this is the pipe out i did for the mains pressure hot water cylinder |

here is a view of my valve train and tempering valve and a view of how i have connected them together.
here is my valve train- 1. wing back 2. non return 3. a 3 in one valve 4. cold water expansion
here i have the cold water expansion and the pressure relief pipes connected to each other because these two pipes constantly discharge water and the water then is discharged to tun dish at the bottom of the safe tray.
over here i have the pressure relief drain pipe connected to the cold water expansion drain and discharging at the tun dish at the bottom of the safe tray.
here is the pipe connecting from the top out let to the tempering valve as hot mixing with the cold
![]() |
here is the hot water out let croxed and conected to the tempering valve and also the pressure relief pipe croxed and connected to the cold water expansion pipe discharging out to the drain |
![]() |
here is my low pressure cylinder and me pointing at the pipe coming out from the bottom drain of the cylinder |
![]() |
completion of my low pressure system open vented |
Brazing training of all types of joints |
my formed 45 degree 15 mm on a 20 mm joint. |
a view of how i form the formed joints |
i have completed a low pressure system with ease after planning out how to do them. also there is photos showing what i have learnt about brazing and making different types of joints.
i have more pictures of the other practical i have completed:
this square is made up of copper pipe, sht pipe, and steel pipe.
steel pipe legnth- 400mm bent at 200mm centre
copper pipe legnth- 400mm bent at 200mm centre also with a 100 mm croxed t joined for air/water testing.
sht pipe legnth- 400mm bent at 200 mm centre wih an elbow
in this picture i have piped out a basin with two separate copper pipes bent at a 45 degree angle for hot water and cold water feeding to the taps.
it is soldered and spot welded at the bottom of the head so that there is no marks in the front of it as it will be visible and wont look good
this part of the rollover stack that i have completed
here is the vent pipe again part of the rollover stack
this also part of the rollover stack
this the rain water head which i have created with sheet metal
it is soldered and spot welded at the bottom of the head so that there is no marks in the front of it as it will be visible and wont look good